Huawei Router NE40E-X16
-
Price:
Negotiable
- minimum:
- Total supply:
-
Delivery term:
The date of payment from buyers deliver within days
-
seat:
Guangdong
-
Validity to:
Long-term effective
-
Last update:
2020-02-13 11:15
-
Browse the number:
296
+
- Contactaixin:
kuyuekeji(Mr.)
- Email: telephone: phone:
-
Arrea:
Guangdong
Address:B-1906, Zhantao-Tech Mansion, Minzhi Road 1079, Longhua District, Shenzhen, 518110, China
- Website:
+
Overview |
Table 1 Device attributes | ||||
Product Type |
Description |
BOM |
Model |
Earliest Software Version |
NE40E-X16 |
NE40E-X16 Integrated Chassis Components (Including 8 DC Power) |
02351931 |
CR5B0BKP1670 |
V800R006C20 |
Appearance of Huawei NE40E-X16 |
Figure 1 Appearance
Components |
Figure 2 Components
1. Air intake frame |
2. MPU |
3. Front cable trough |
4. SFU |
5. LPU |
6. Handle |
7. Mounting ear |
8. Fan module |
9. Filler panel |
10. Power entry module (PEM) NOTE: |
11. Rear cable trough |
12. Power management interface |
13. Ground terminal |
14. ESD jack (rear) |
15. (Optional) Central monitoring module |
Slot Layout |
Figure 3 Slot layout
Table 2 Description of slot layout | |||
Slot Name |
Slot Quantity |
Slot ID |
Remarks |
LPU |
16 |
1 to 16 |
These slots hold LPUs. |
MPU |
2 |
17 to 18 |
These slots hold MPUs. |
SFU |
4 |
19 to 22 |
These slots hold SFUs. |
Interface Numbering |
An interface is numbered in the format of slot number/card number/port number
NOTE:
Slot number: The slots of LPUs are numbered from 1 to 16. The slot number increases from left to right and from top to bottom, facing the front panel of the NE40E (there are corresponding marks on the panel).
Card number:
●Upper chassis
●The cards of LPUs are numbered from top to bottom and from right to left beginning with 0. If there is no card on a board, the card number is set to 0.
●Lower chassis
●The cards of LPUs are numbered from bottom to top and from left to right beginning with 0. If there is no card on a board, the card number is set to 0.
Port number:
●Upper chassis
●The ports of LPUs are numbered from left to right and from top to bottom beginning with 0.
●Lower chassis
●The ports of LPUs are numbered from right to left and from bottom to top beginning with 0.
Technical Specifications of Huawei NE40E-X16 |
Item |
Specification |
Dimensions (H x W x D) |
●(32 U) 1420 mm x 442 mm x 650 mm (55.91 in. x 17.40 in. x 25.59 in.) (Chassis main body) ●(32 U) 1420 mm x 442 mm x 770 mm (55.91 in. x 17.40 in. x 30.31 in.) (Dimensions of the chassis body together with cable trays and front and back attachments) |
Weight (empty) |
69.6 kg (153.47 lb) (without filler panels) |
Weight (full configuration) |
279 kg (615.2 lb) |
Cabinet installation standard |
Can be installed in a standard 19" 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default. |
Typical power consumption |
6210 W (fully configured with LPUF-240s) |
Typical heat dissipation |
20147.9 BTU/hour (fully configured with LPUF-240s) |
DC input voltage |
●input voltage range: –38.4 V to –72 V ●input rated voltage: –48 V/ –60 V |
AC input voltage |
●input voltage range: 180 V to 264 V ●input rated voltage: 200 V to 240 V |
MTBF |
21.66 years |
MTTR |
0.5 hours |
Availability |
0.999997365 |
Slot quantity |
22 |
Redundant MPUs |
1:1 |
Redundant Switch fabrics |
3+1 |
Redundant fans |
●2 partitions ●2 assemblies/partition, each partition in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) |
Redundant power supply |
4+4 |
Forwarding performance |
5760 Mpps (LPUF-240) |
Switching capacity |
12.58 Tbps (LPUF-240/LPUI-240) |
Operating temperature |
●Long-term: 0°C to 45°C (32°F to 113°F) ●Short-term: –5°C to +55°C (23°F to131°F) ●Remark: Restriction on the temperature variation rate: 30°C/hour (86°F/h) |
Storage temperature |
–40°C to +70°C (–40°F to +158°F) |
Relative operating humidity |
●Long term: 5% to 85% RH, non-condensing ●Short term: 5% to 95% RH, non-condensing |
Relative storage humidity |
5% to 95% RH, non-condensing |
Long-term operating altitude |
<= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the NEU100 must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].) |
Storage altitude |
Less than 5000 m (16404 ft.) |